Professional Committee of Rock and Mineral Testing Technology of the Geological Society of China, National Geological Experiment and Testing CenterHost
2013 Vol. 32, No. 2
Article Contents

Gui HE, Ji-xiu CHANG, Xiao-run ZHOU, Lu-jun WANG. Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry[J]. Rock and Mineral Analysis, 2013, 32(2): 229-243.
Citation: Gui HE, Ji-xiu CHANG, Xiao-run ZHOU, Lu-jun WANG. Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry[J]. Rock and Mineral Analysis, 2013, 32(2): 229-243.

Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry

More Information
  • Abstract: During the analyses of ore and rock samples by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS), many residues were formed in the tubes in which the hydride was generated, transport channelled and atomized. If a certain amount of the residues accumulat, they can distinctively affect the detection sensitivity of Se and Te. Many coexisting ingredients in the samples have a large influence on the detection of Se and Te by HG-AFS. In this article, to avoid interference from these ingredients, the series of standard solutions prepared with highly pure material were used. The standard solutions were tested with used tubes and cleaned ones. Through comparison of the data of the standard solutions, it was demonstrated that the residues in the instrument affected the detection of Se and Te by making the detection sensibility lower and the linear correlation coefficient smaller. The residues were analyzed with Atomic Fluorescence Spectrometry, Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission Spectrometry. On the basis of the analytical results of the residues, Ti, Cu, As, Sb and Bi have great effect on the detection sensitivity and the linear correlation coefficient of Se and Te. These elements are a part of the coexisting interferences mentioned in literatures. When the tubes were cleaned, the measured quality was remarkably improved with higher sensitivity, and the linear correlation coefficient was more than 0.9995. According to the data obtained in this study, indications are that the analysis of residue components in the tubes is one of the effective methods to control the interference of HG-AFS.
  • 加载中
  • [1] 岩石矿物分析编写组.岩石矿物分析(第四版 第三分册)[M].北京:地质出版社,2011: 590-591.

    Google Scholar

    [2] 王烨.活性炭分离氢化物原子荧光光谱法测定金矿中微量硒[J].地质实验室,1989,5(4): 204-205.

    Google Scholar

    [3] 李刚,李文莉.氢化物-原子荧光光谱法测定铜矿中微量硒和碲[J].岩矿测试, 2002,21(3): 223-226.

    Google Scholar

    [4] 范凡.氢化物发生-原子荧光光谱法测定地球化学样品中痕量碲[J].岩矿测试,2005,24(3): 225-228.

    Google Scholar

    [5] 耿学道.氢化物原子吸收法测定矿石及地球化学样品中微量硒、碲[J].岩矿测试,1986,5(1): 58-61.

    Google Scholar

    [6] 林猷璧,朱玉伦.M17树脂分离富集原子荧光测定岩矿中痕量碲[J].岩矿测试,1991,10(4): 283-286.

    Google Scholar

    [7] 肖清书,夏峰,张文.原子荧光光谱法连续测定土壤样品中微量铋、碲[J].中国环境监测,1990,6(1):67-69.

    Google Scholar

    [8] 杨冀华,杜新军,朱永昌.流动注射-原子荧光光谱法测定岩矿中痕量硒和碲[J].岩矿测试,1996,15(1):61-64.

    Google Scholar

    [9] 吕运开,孙汉文.尿中痕量碲测定的萃取-氢化物发生原子荧光光谱法[J].分析测试学报,2000,19(4): 24-27.

    Google Scholar

    [10] 任萍,张勤,张锦茂.焙烧富集分离-氢化物原子荧光光谱法测定地质物料中痕量硒[J].分析试验室,1994,13(4): 65-67.

    Google Scholar

    [11] 田莉玉,刘淑芹,马丽艳.在碱性条件下氢化物原子荧光光谱法测定岩石样品中碲[J].分析试验室,2003,22(3): 50-51.

    Google Scholar

    [12] 向祥蓉,刘虹,王佼.氢化物发生-原子荧光光谱法测定Inconel718合金中痕量硒[J].分析仪器,2012(2): 37-40.

    Google Scholar

    [13] 刘红波,钟平,邓修龙,郭艳静.氢化物发生-原子荧光光谱法测定赣南脐橙中的硒[J].食品研究与开发,2010,31(1): 126-128.

    Google Scholar

    [14] 郭小伟,张文琴,杨密云.氢化物-无色散原子荧光光谱法测试地质样品中微量硒及碲[J].岩矿测试,1983,2(4): 288-292.

    Google Scholar

    [15] 贾喜英,陈新民,许晓洁.原子荧光光谱法测定化探样品中微量硒、碲[J].西部探矿工程,2002(5): 68,70.

    Google Scholar

    [16] 柴昌信,陈世焱,陈月源.氢化物发生-原子荧光光谱法直接测定多金属矿中的硒和碲[J].岩矿测试,2009,28(2): 143-146.

    Google Scholar

    [17] 丁秘枣.氢化物原子荧光光谱法测定化探样品中碲[J].地质实验室,1998,14(1): 21-22.

    Google Scholar

    [18] 张锦茂,范凡,任萍.氢化物-原子荧光光谱法测定岩石中痕量硒的干扰及消除[J].岩矿测试,1993,12(4): 264-267.

    Google Scholar

    [19] 陈仲仁.氢化物-无色散原子荧光光谱法测定化探样品中痕量硒[J].地质实验室,1989,5(3): 162-165.

    Google Scholar

    [20] 雷汉云.氢化物双道无色散原子荧光光谱法同时测定化探样品微量硒、碲[J].有色金属矿产与勘查,1995,4(4): 233-236.

    Google Scholar

    [21] 林光西.氢化物发生-原子荧光光谱法直接测定地球化学样品中痕量碲[J].岩矿测试,2008,27(2): 151-152.

    Google Scholar

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Tables(6)

Article Metrics

Article views(373) PDF downloads(1) Cited by(0)

Access History

Other Articles By Authors

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint