Comparison of Ashing and Microwave Digestion in Analyzing Geoelectrochemical Polyurethane Foam Samples

More Information
  • Currently, the ashing method is widely used to pretreat geo-electrochemical polyurethane foam samples. However, there may be volatilization loss of some elements such as Hg and As under high temperature. A geo-electrochemical exploration line in Luokedun hydrothermal lead-zinc polymetallic deposit in Inner Mongolia was selected as the research subject. A comparison of the exploration effects between the ashing method and microwave digestion in pretreating foam samples was made, and the contents of some related elements by High Resolution Inductively Coupled Plasma-Mass Spectrometry (HR-ICP-MS) and Atomic Fluorescence Spectrometry (AFS) were measured. Results are as follows, ①For more than ten elements including Zn, Cu, Fe, and La, abnormal patterns of the two methods were identical within uncertainty measurements and thus both methods can be used according to the work requirement. ②For Au and Pb, microwave digestion has serious problems related to homogeneity, representative and detection limit due to the small sample volume, making ashing the more suitable method. ③There is a significant loss in ashing for Hg, so microwave digestion is more suitable. ④For As, both analytical methods suffer a lot problems, therefore, dissolving the samples directly by nitric and perchloric acid using the pretreatment method for plant samples would be the preferable method.
  • 加载中
  • [1] Leinz R W,Hoover D B,Fey D L,et al. Electrogeochemical Sampling with NEOCHIM-Results of Tests over buried Gold Deposits[J].Journal of Geochemical Exploration,1998,61(1):57-86.

    Google Scholar

    [2] 刘占元,程志中,孙彬彬.电提取技术中载体物质应用效果提高的途径[J].物探与化探,2005,29(5):401-403.

    Google Scholar

    Liu Z Y,Cheng Z Z,Sun B B.The Processing of the Carrier Material in the Cathode Receiver[J].Geophysical & Geochemical Exploration,2005,29(5):401-403.

    Google Scholar

    [3] Luo X R,Hou B H,Wen M L,et al.CHIM-Geoelectrochemical Method in Search of Concealed Mineralization in China and Australia[J].Chinese Journal of Geochemistry,2008,27(2):198-202.

    Google Scholar

    [4] 李天虎,罗先熔,彭桥梁,等.甘肃金川铜镍矿床Ⅰ矿区深部边部地质-地电化学-地球物理多元信息成矿预测[J].地质通报,2012,31(7):1192-1200.

    Google Scholar

    Li T H,Luo X R,Peng Q L,et al.Geological-Geoelectrochemical-Geophysical Multifactor Information Ore Prognosis in the Depth and on the Edge of No.Ⅰ Mining Area of the Jinchuan Copper-Nickel Sulfide Ore Deposit,Gansu Province[J].Geological Bulletin of China,2012,31(7):1192-1200.

    Google Scholar

    [5] 孙彬彬,刘占元,周国华.固体载体型元素提取器研制[J].物探与化探,2011,35(3):375-378.

    Google Scholar

    Sun B B,Liu Z Y,Zhou G H.The Development of the Solid Carrier Elements Exstractor[J].Geophysical & Geochemical Exploration,2011,35(3):375-378.

    Google Scholar

    [6] 孙彬彬,刘占元,周国华.地电化学方法技术研究现状及发展趋势[J].物探与化探,2015,39(1):16-21.

    Google Scholar

    Sun B B,Liu Z Y,Zhou G H.Research Status and Development Trends for Geoelectrochemical Methods[J]. Geophysical & Geochemical Exploration,2015,39(1):16-21.

    Google Scholar

    [7] 张勤,白金峰,王烨.地壳全元素配套分析方案及分析质量监控系统[J].地学前缘,2012,19(3):33-42.

    Google Scholar

    Zhang Q,Bai J F,Wang Y.Analytical Scheme and Quality Monitoring System for China Geochemical Baslines[J].Earth Science Frontiers,2012,19(3):33-42.

    Google Scholar

    [8] 刘亚轩,李晓静,白金峰,等.植物样品中无机元素分析的样品前处理方法和测定技术[J].岩矿测试,2013,32(5):681-693.

    Google Scholar

    Liu Y X,Li X J,Bai J F,et al.Review on Sample Pretreatment Methods and Determination Techniques for Inorganic Elements in Plant Samples[J].Rock and Mineral Analysis,2013,32(5):681-693.

    Google Scholar

    [9] 陈亚东,孙彬彬,刘占元,等.地电化学提取有效性及提取条件实验——以半干旱草原风成沙浅覆盖景观区为例[J].物探与化探,2015,39(5):1008-1012.

    Google Scholar

    Chen Y D,Sun B B,Liu Z Y,et al.Geoelectrochemical Extraction Effectiveness and Conditions Test-Taking Semi-arid Grasslands Aeolian Shallow Overburden Areas as an Example[J].Geophysical & Geochemical Exploration, 2015,39(5):1008-1012.

    Google Scholar

    [10] 李刚,高明远,诸堃.微波消解-电感耦合等离子体质谱法测定植物样品中微量元素[J].岩矿测试,2010,29(1):17-22.

    Google Scholar

    Li G,Gao M Y,Zhu K.Determination of Micro-amount of Elements in Plant Samples by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion[J].Rock and Mineral Analysis, 2010,29(1):17-22.

    Google Scholar

    [11] 唐兴敏,任小荣,方雅琴.微波消解-ICP-OES法测定植物样品中磷锌钡铁锰镁钙锶等八项微量元素[J].资源环境与工程,2013,27(6):831-834.

    Google Scholar

    Tang X M,Ren X R,Fang Y Q.Determination of Eight Trace Elements of P,Zn,Ba,Fe,Mn,Mg,Ca,Sr in Plants by ICP-OES with Microwave Digestion[J].Resources Environment & Engineering,2013,27(6):831-834.

    Google Scholar

    [12] 聂凤莲,艾晓军,逮艳军.地电化学(泡塑)样品中金的预处理[J].黄金科学技术,2007,15(6):52-55.

    Google Scholar

    Nie F L,Ai X J,Dai Y J.Pretreatment of Au Geoelectrical Chemical Samples(Foam)[J].Gold Science and Technology,2007,15(6):52-55.

    Google Scholar

    [13] 施意华,杨仲平,黄俭惠,等.ICP-MS测定电吸附找矿泡塑样品中微量元素[J].光谱学与光谱分析,2009,29(6):1687-1690.

    Google Scholar

    Shi Y H,Yang Z P,Huang J H,et al.Determination of Trace Elements in Electrical Absorption Prospecting Polyform Sample by Inductively Coupled Plasma Mass Spectrometry[J].Spectroscopy and Spectral Analysis, 2009,29(6):1687-1690.

    Google Scholar

    [14] 李晓辉,王亮.内蒙古自治区东乌珠穆沁旗洛恪顿铅锌多金属矿详查年度总结报告[R].内蒙古赤峰地质矿产勘查开发院,2013.

    Google Scholar

    Li X H,Wang L.Detailed Survey Annual Summary Report of Luokedun Pb-Zn Polymetallic Deposit in Dong Ujimqin Banner,Inner Mongolia[R].Inner Mongolia ChiFeng Geology and Mineral Exploration and Development,2013.

    Google Scholar

    [15] 周红,谭克仁,聂凤莲,等.地电化学(泡塑)样品中金与锑的预处理[J].岩矿测试,2004,23(4):303-306.

    Google Scholar

    Zhou H,Tan K R,Nie F L,et al.Pretreatment of Au and Sb in Geoelectrical Chemical Samples[J].Rock and Mineral Analysis,2004,23(4):303-306.

    Google Scholar

    [16] 聂凤莲,张蜀冀,陈雪,等.ICP-MS法测定地电化学(泡塑)样品中痕量金[J].黄金,2011,32(12):58-60.

    Google Scholar

    Nie F L,Zhang S J,Chen X,et al.Determination of Trace Gold in Geoelectrical Chemical Samples (Foam) by ICP-MS Method[J].Gold,2011,32(12):58-60.

    Google Scholar

    [17] 王小平,马以瑾,徐元春.原子荧光光谱法测定不同产地茶叶中的As,Se,Hg和Bi四种元素含量[J].光谱学与光谱分析,2008,28(7):1653-1657.

    Google Scholar

    Wang X P,Ma Y J,Xu Y C.Studies on Contents of Arsenic,Selenium,Mercury and Bismuth in Tea Samples Collected from Different Regions by Atomic Fluorescence Spectrometry[J].Spectroscopy and Spectral Analysis, 2008,28(7):1653-1657.

    Google Scholar

    [18] 赵斌,陈志兵,董丽.氢化物发生-原子荧光光谱法测定植物样品中汞硒砷[J].岩矿测试,2010,29(3):319-321.

    Google Scholar

    Zhao B,Chen Z B,Dong L.Determination of Hg,Se and As in Plant Samples by Hydride Generation-Atomic Fluorescence Spectrometry[J].Rock and Mineral Analysis,2010,29(3):319-321.

    Google Scholar

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(3)

Tables(1)

Article Metrics

Article views(1349) PDF downloads(60) Cited by(0)

Access History

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint