2025 Vol. 34, No. 2
Article Contents

ZHANG Hua, HAO Shu-ren, LIU Li-hong, DONG Wu-jun, CHENG Tong, HU Hui-juan. Influence of long-term operation of ground source heat pump on geothermal field in heat transfer area[J]. Geology and Resources, 2025, 34(2): 246-254. doi: 10.13686/j.cnki.dzyzy.2025.02.012
Citation: ZHANG Hua, HAO Shu-ren, LIU Li-hong, DONG Wu-jun, CHENG Tong, HU Hui-juan. Influence of long-term operation of ground source heat pump on geothermal field in heat transfer area[J]. Geology and Resources, 2025, 34(2): 246-254. doi: 10.13686/j.cnki.dzyzy.2025.02.012

Influence of long-term operation of ground source heat pump on geothermal field in heat transfer area

More Information
  • To study the influence of long-term operation of ground source heat pump (GSHP) on geothermal field in heat transfer area of hot-summer and cold-winter regions, taking a GSHP project in Nanchang City as an example, this paper analyzes the variation characteristics of geothermal field and heat-cold accumulation inside and outside the heat transfer area of the demonstration project over four years of operation. The project arranges seven temperature monitoring holes in the center and surrounding areas of the GSHP group for comprehensive monitoring of geothermal field changes in heat transfer area during the four-year operation. The analysis results show that the geothermal temperature inside and outside the heat transfer area changes periodically with the four-year operation of GSHP; The geothermal temperature increases with increasing depth vertically, and the variation range decreases gradually; Radially, geothermal temperature variations around the heat transfer area gradually decreases with increasing distance from hole group; The thermal influence radius of the hole group is 3-6 m during the four-year operation; The average temperature at the hole group boundary increases merely by 0.13 ℃, indicating insignificant heat accumulation after the four-year operation. These findings provide references for the site design of GSHP heat transfer holes.

  • 加载中
  • [1] 王小清, 王万忠. 地埋管地源热泵系统运行期地温监测与分析[J]. 上海国土资源, 2013, 34(2): 76-79.

    Google Scholar

    Wang X Q, Wang W Z. Soil-temperature monitoring and analysis of a ground source heat pump system during the operating period[J]. Shanghai Land & Resources, 2013, 34(2): 76-79.

    Google Scholar

    [2] 庄宇, 潘小平. 地源热泵空调系统的换热工区岩土体温度变化研究[J]. 水文地质工程地质, 2010, 37(6): 134-138.

    Google Scholar

    Zhuang Y, Pan X P. A study of the soil temperature change caused by GSHP air-conditioning system[J]. Hydrogeology & Engineering Geology, 2010, 37(6): 134-138.

    Google Scholar

    [3] 孙婉, 周念清, 黄坚, 等. 地源热泵系统运行换热区内外地温场变化特征分析[J]. 太阳能学报, 2017, 38(10): 2804-2810.

    Google Scholar

    Sun W, Zhou N Q, Huang J, et al. Analysis of ground temperature field change characteristics for inside and outside heat exchange area of ground source heat pump system operation[J]. Acta Energiae Solaris Sinica, 2017, 38(10): 2804-2810.

    Google Scholar

    [4] 姚木申, 袁小飞, 卢宝. 地源热泵系统地下温度场变化及其对系统COP的影响[J]. 制冷与空调, 2016, 16(8): 85-89, 96.

    Google Scholar

    Yao M S, Yuan X F, Lu B. Change of underground temperature field of ground-source heat pump system and its influence on COP of system [J]. Refrigeration and Air-Conditioning, 2016, 16(8): 85-89, 96.

    Google Scholar

    [5] 高世轩. 上海地源热泵系统对地质环境的热影响分析[J]. 上海国土资源, 2012, 33(1): 67-70.

    Google Scholar

    Gao S X. Analyzing the influence of heat on the geological environment surrounding ground source heat pump system in Shanghai[J]. Shanghai Land & Resources, 2012, 33(1): 67-70.

    Google Scholar

    [6] 梁欣阳, 赵雪红, 王青. 地埋管地源热泵工程运行换热区温度场变化特征分析[J]. 地下水, 2022, 44(6): 11-16.

    Google Scholar

    Liang X Y, Zhao X H, Wang Q. Characteristics of temperature field in ground-source heat pump system[J]. Ground Water, 2022, 44(6): 11-16.

    Google Scholar

    [7] 李新国, 赵军, 周倩. U型垂直埋管换热器管群周围土壤温度数值模拟[J]. 太阳能学报, 2004, 25(5): 703-707.

    Google Scholar

    Li X G, Zhao J, Zhou Q. Numerical simulation on the ground temperature field around U pipe underground heat exchangers[J]. Acta Energiae Solaris Sinica, 2004, 25(5): 703-707.

    Google Scholar

    [8] 刘俊, 张旭, 高军, 等. 地源热泵土壤温度恢复特性研究[J]. 暖通空调, 2008, 38(11): 147-150.

    Google Scholar

    Liu J, Zhang X, Gao J, et al. Research of soil temperature restoration characteristics of ground-source heat pump systems[J]. Heating Ventilating & Air Conditioning, 2008, 38(11): 147-150.

    Google Scholar

    [9] 张晓明, 吴建坤, 魏凌敏. 垂直U型管换热器周围土壤温度场的数值模拟[J]. 沈阳建筑大学学报(自然科学版), 2011, 27(1): 111-114, 145.

    Google Scholar

    Zhang X M, Wu J K, Wei L M. Numerical simulation on soil temperature field around vertical U-tube heat exchangers[J]. Journal of Shenyang Jianzhu University (Natural Science), 2011, 27(1): 111-114, 145.

    Google Scholar

    [10] 姜振涛. 单U型垂直埋管换热器放热期土壤温度场的试验研究及数值分析[D]. 太原: 太原理工大学, 2012.

    Google Scholar

    Jiang Z T. Experimental research and numerical analysis on soil temperature field of single U-tube heat exchanger vertically buried in heat release period[D]. Taiyuan: Taiyuan University of Technology, 2012.

    Google Scholar

    [11] 张也, 骆祖江, 杜建国, 等. 基于热平衡原理的地埋管地源热泵系统开发利用潜力评价[J]. 太阳能学报, 2022, 43(9): 444-452.

    Google Scholar

    Zhang Y, Luo Z J, Du J G, et al. Potential evaluation of development and utilization of ground source heat pump system based on heat balance principle[J]. Acta Energiae Solaris Sinica, 2022, 43(9): 444-452.

    Google Scholar

    [12] 管昌生, 万兆, 胡平放. 地源热泵地埋管多层岩土温度场的数值分析[J]. 武汉工程大学学报, 2011, 33(4): 42-45.

    Google Scholar

    Guan C S, Wan Z, Hu P F. Numerical analysis on multilayer geotechnical temperature field of GSHP buried tube[J]. Journal of Wuhan Institute of Technology, 2011, 33(4): 42-45.

    Google Scholar

    [13] 王洋, 王小清, 李雷雷, 等. 基于监测数据的地埋管地源热泵系统运行策略优化[J]. 暖通空调, 2018, 48(1): 158-163.

    Google Scholar

    Wang Y, Wang X Q, Li L L, et al. Operation strategy optimization of ground source heat pump system based on monitoring data[J]. Heating Ventilating & Air Conditioning, 2018, 48(1): 158-163.

    Google Scholar

    [14] 于慧明, 杨泽, 都基众. 基于层次分析法的沈阳市地埋管地源热泵适宜性评价[J]. 地质与资源, 2016, 25(6): 563-566. DOI: 10.13686/j.cnki.dzyzy.2016.06.009.

    CrossRef Google Scholar

    Yu H M, Yang Z, Du J Z. AHP-Based suitability zonation and assessment for the ground-source heat pump system in Shenyang City [J]. Geology and Resources, 2016, 25(6): 563-566. DOI: 10.13686/j.cnki.dzyzy.2016.06.009.

    CrossRef Google Scholar

    [15] Luo J, Rohn J, Bayer M, et al. Heating and cooling performance analysis of a ground source heat pump system in Southern Germany [J]. Geothermics, 2015, 53: 57-66.

    Google Scholar

    [16] 姚远. 基于实测的地埋管地源热泵空调技术的节能与应用分析[D]. 武汉: 武汉科技大学, 2010: 28-33.

    Google Scholar

    Yao Y. The energy conservation and technology using analysis of ground source heat pump based on actual survey[D]. Wuhan: Wuhan University of Science and Technology, 2010: 28-33.

    Google Scholar

    [17] 张甫仁, 王乐祥, 李雪洋, 等. 重庆市浅层地温能开发利用地温场变化规律研究[J]. 重庆交通大学学报(自然科学版), 2018, 37 (2): 76-81.

    Google Scholar

    Zhang F R, Wang L X, Li X Y, et al. Geo-temperature change law caused by shallow geothermal energy utilization in Chongqing[J]. Journal of Chongqing Jiaotong University (Natural Science), 2018, 37(2): 76-81.

    Google Scholar

    [18] 魏静, 高世轩, 孙婉. 上海地区地源热泵工程地温场特征试验研究[J]. 暖通空调, 2015, 45(6): 41-46.

    Google Scholar

    Wei J, Gao S X, Sun W. Experimental study of ground temperature field characteristics surrounding GSHP system in Shanghai[J]. Heating Ventilating & Air Conditioning, 2015, 45(6): 41-46.

    Google Scholar

    [19] 王子珑, 梅新忠, 王楠, 等. 地埋管地源热泵长期运行地温变化及系统性能监测与分析[J]. 河北工业大学学报, 2019, 48(6): 82-86, 92.

    Google Scholar

    Wang Z L, Mei X Z, Wang N, et al. Monitoring and analysis of ground temperature variations and system performance of a buried-pipe ground source heat pump during the long-term operation[J]. Journal of Hebei University of Technology, 2019, 48(6): 82-86, 92.

    Google Scholar

    [20] 李少华, 林清龙, 段新胜, 等. 杭州某地埋管地源热泵系统地温场监测与分析[J]. 暖通空调, 2020, 50(8): 70-74.

    Google Scholar

    Li S H, Lin Q L, Duan X S, et al. Monitoring and analysis of ground temperature field of a GSHP in Hangzhou[J]. Heating Ventilating & Air Conditioning, 2020, 50(8): 70-74.

    Google Scholar

    [21] 刘杰. 浅层地热能开发利用地质环境影响与监测系统建设研究[J]. 山东国土资源, 2018, 34(1): 49-55.

    Google Scholar

    Liu J. Study on impact of the development and utilization of shallow geothermal energy to geological environment and monitoring system construction[J]. Shandong Land and Resources, 2018, 34(1): 49-55.

    Google Scholar

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(6)

Tables(4)

Article Metrics

Article views(122) PDF downloads(26) Cited by(0)